Channel Avatar

RELAY PROTECTION ELECTRICAL @UCs7vZxJY-WHeFh3_I9IjQoA@youtube.com

15K subscribers - no pronouns :c

Hi friends this channel is all about sharing of my experienc


09:05
Short Circuit MVA ( 3-Ph & 1Ph-G) & Equivalent Impedance (Positive, Negative & Zero Seq. Impedance )
08:24
Wattmeter Reading || Positive and Negative Reading for 3 Ph 4 Wire Wattmeter in a Sub Station
04:35
Ferruling Standard for CT wiring in a Sub Station CT secondary circuit
04:48
Use of NCT(Neutral Current Transformer) in Double Star Capacitor Bank
05:28
Knee Point Voltage Vk for Current Transformer for Restricted Earth Fault ( REF) Protection
05:58
DISTRUBUTED BUS BAR PROTECTION RELAY
09:52
Distance Relay Micom P441, P442 and P444 Relay Wiring Terminal and Binary Input and Binary Output
11:02
BUS BAR PROTECTION FOR TWO BUS SYSTEM || BIAS AND DIFFERENTIAL CURRENT FOR ZONE-A & B & Check Zone
06:24
CT(Current Transformer) V/S PT(Potential Transformer)
06:17
Teed Differential Protection of One and Half Breaker System
03:40
Selection of HV Side and LV side CT Ratio for Power Transformer
17:56
Over current Relay Coordination for a Sub Station|| Case-2
06:24
Case Study: Differential Relay || Trip Phase A and Phase B
21:19
OVER CURRENT RELAY COORDINATION IN A SUB STATION || TWO NOS TRANSFORMERS RUNNING IN PARALLEL||Case-I
06:03
DISTANCE RELAY || Primary to Secondary Impedance Conversion
04:57
Over Current Relay Coordination in a Sub Station
08:34
Current Transformer (CT) Polarity and Methods for Changing CT Polarity for Protection system
11:09
Function of DC Selector Switch in Control and Relay Panel for double DC source
08:00
Line Earth Switch (89LE) Interlock for Transmission Line in a Sub Station
09:26
PT(Potential Transformer)Selection Scheme for Two Main Bus System ( 75A and 75B Relay)
12:21
Current Transformer (CT) Wiring Diagram for Metering Circuit in CRP for FDR
07:27
Importance of Core Selection Test of CT|| What will happen if Metering Core is Connected to Relay
06:07
Difference between Isolator and Circuit Breaker in a Sub Station
09:35
Current Transformer (CT) ISF(Instrument Safety Factor) V/S ALF (Accuracy Limit Factor)
07:50
Protection of Teed Feeder for Transmission Line || Overcome Difficulty for Distance Relay Settings
11:33
11 KV VCB CLOSING AND TRIPPING OPERATION WIRING DIAGRAM
11:32
Current Transformer (CT) Wiring Diagram for 11KV Switch Gear Panel
10:02
Trip Transfer Scheme for Sub Station|| How trip is Transferred to TBC Breaker
09:19
Directional Over current Relay and Cross Polarization Method
10:02
Impact of Different Transformers with different Percentage Impedance under Parallel Operation
04:59
Difference Between High Impedance BusBar Protection Relay and Low Impedance BusBar Protection Relay
06:07
End Fault Protection or Dead Zone Fault Protection for Bus Bar Relay
09:48
BUS Bar Protection for Two Main Bus and One Transfer Bus System (Part-3)
14:44
BUSBAR PROTECTION FOR TWO BUS SYSTEM (PART-2)|| CONCEPT OF CHECK ZONE DIFFERENTIAL CURRENT
18:54
Bus Bar Protection for Two Bus System (Part-1)
11:11
Motor Earth Fault Relay||Stabilizing Resistance Rs for Motor Earth Fault Protection
09:14
Earth Fault Relay Setting|| Impact of wrong Coordination for Earth Fault in Distribution System
06:42
3-Phase Motor Protection|| Single Phase Preventer(SPP) for protection of Motor from phase Failure
07:00
Fault Level Calculation for 33 KV Bus || 3-Ph Symmetrical Fault
07:00
How Much Winding is Protected by Differential Relay for Fault in Star Side of the Transformer
04:15
How to Calculate Lightning Arrester (LA) Rating for different System Voltage
07:35
Fault Current Calculation for Transmission Line and Simulation in ETAP
07:38
Fault Current Calculation and Simulation in ETAP for Parallel Operation of Transformer 33/11kV 10MVA
01:53
What is Differential Zone for Transformer
08:47
Zero Sequence Current Filtering for Differential Relay of Power Transformer
13:30
BACK UP OVERCURRENT AND EARTH FAULT PROTECTION OF TRANSFORMER WITH RELAY COORDINATION
06:07
Transformer Testing|| Tan Delta Test of Transformer Winding|| UST, GST and GSTg mode in Hindi
12:57
Static Differential Relay|| How phase and Magnitude Correction is done by using ICT
08:02
Different Parts of 11 KV VCB ( VACCUM CIRCUIT BREAKER) Switchgear and their Functions
10:10
RESTRICTED EARTH FAULT RELAY LOW IMPEDANCE TYPE || OPERATING PRINCIPLE
14:38
RELAY COORDINATION || MPACT OF WRONG RELAY SETTINGS COORDINATION IN DISTRIBUTION SUB STATION
07:19
Current Distribution In a Delta Star Transformer for 3-PH , Double Phase and Phase to Ground Fault
07:38
Transformer Protection|| Function of Buchholz Relay || Buchholz Alarm and Buchholz Trip
12:59
Transformer Testing|| Magnetisation Current Test of 3 PH Transformer (in Hindi) हिंदी में
10:59
Function of CVT ( CAPACITIVE VOLTAGE TRANSFORMER) IN A SUB STATION
13:36
Distance Relay|| Impact of Kz Zero Sequence Compensation Factor Distance Relay Reach for Earth Fault
10:28
CT Polarity and CT Star Point Connection for Transmission Line Protection in Hindi
08:11
ISF (Instrument Security Factor) and CT Burden for Metering Class Current Transformer
09:29
Matching Factor and Per Unit (PU) Current for Differential Relay (in Hindi) हिंदी में
08:46
Matching Factor and Per Unit (PU) Current for Differential Relay