MikeHoltNEC @UC8oJL9T1z3Gqn6drDphZY6g@youtube.com

118K subscribers - no pronouns :c

Electrical Education


Neutral-to-ground bond at services and sub-panels explained. Electrical equipment must be installed in a professional and skillful manner. Unused openings on electrical equipment must be closed to afford protection. A non-separately derived generator does not need a ground rod, watch MikeHolt.com/Fundamentals Flush-mounted boxes in noncombustible or combustible material. NEC 314.20 Receptacles for Electric Vehicle (EV) charging must be GFCI protected in accordance with 625.54. Neutral-to -ground bond required at service and not permitted at subpanel. Work with me or get Banned from my Channel NFPA and Mike Holt Enterprises Continue the Partnership for 2026 Changes Book! VIOLATION: The neutral conductor identification required by 200.6(B) is not at its terminations. You have to use the correct screw when you secure a panel... I'm like what? A feeder neutral conductor is not required at a panel or disconnect, unless the neutral is needed. You don't need to adjust the ampacity for current-carrying conductors bundled in a panel [310.14(A)] When more than three current conductors are bundled for more than 24", the ampacity must be adjusted The NEC permits spare raceways from a panel and it does not require that an enclosure be installed. Insulated neutral conductors 6 AWG and smaller must be identified white or grey per NEC 200.6(A). If you get the Neanderthal attitude (get it done), you would accomplish a lot more in your life. Feeders to a dwelling unit are not required to be larger than the service conductors Table 310.12(A) Conductors 4 AWG and larger that enter a raceway must be protected prior to their installation. A receptacle installed under porches can use a snap cover, a bubble cover not required [406.9(A)]. When making splices with twist-type wire connectors, should the wire nut be up or down? The EGC conductor is sized in accordance with Table 250.122, base on the rating of the circuit OCPD. Does the NEC require the GEC to be identified green? No, see 250.62 and 250.119. GEC is not required to be larger than 4 AWG to a rebar electrode and 6 AWG to a ground rod, 250.66. I'm on vacation and I took my bikes with me, but I miss you guys. So no technical message. The conductors for a feeder can be sized using the Mike Holt's Electrical Toolbox. MikeHolt.com/App Only one conductor is permitted to terminate on a terminal, unless identified otherwise. Is AI the future of electrical training? Wishing Mike Holt a Happy Birthday from all of us at Mike Holt Enterprises! 🎉 Wishing Mike Holt a Happy Birthday from all of us at Mike Holt Enterprises! 🎉 The phase conductors of a single-voltage system are not required to be identified, see 310.6(C). Grounding of Remote Buildings [250.32] Can you use the panelboard cabinet as a raceway? I’m praying you are a Young Gun where you have a love for the NEC and are striving for success. What is a young gun? Watch the dinosaurs. Of course splices are permitted in panelboard cabinets, see NEC 312.8(A). Learn why It’s a common practice to improperly install the terminal bar for EGCs. Sealing locknuts not needed if the locknut is located below live parts, see 312.2 and Table 110.28. I often get negative responses. Ensure that your comment has value to the understanding of the NEC. There are hundreds of great individuals working hard to provide us with the NEC for over 125 years. The NEC does not require a connector for the Grounding Electrode Conductor. Remote building disconnect must be located in accordance with NEC 225.31. Let’s learn the rules! Send video of failed wire terminations because antioxidant paste was not used Mike@MikeHolt.com. This post will let me know who’s an electro-dinosaur? Watch MikeHolt.com/AC if you want the facts. No ground rod at this generator! Watch MikeHolt.com/Aux for details. Can LFNC be Buried? What Makes Mike Holt Electrical Apprenticeship Training Unique? Mike Holt takes the stage in Orlando Day 1 to a capacity crowd! #mikeholt #electrician